| Sector | abcHealth Services/Equipments | Tender Value | N.A. | Location | Uttar Pradesh - India | Ref.No | 70042369 | Closing Date | 30 - Apr - 2024 | | | Supply of Group Tender for Various Medical Equipment (g 8-bio Chemistry) (q3) the Glassware Should Be Made of High Quality Borosilicate Glass to Withstand High Heat., 2 Apparatus Capacity Should Be of 4 Litres/hr., 3 Should Be Double Stage., 4 Should Have Metallic Stand and Other Accessories., 5 Stand Should Be Made of Rust Free Material., 6 Standards Heating Elements of 2.5-3kw to Be Used., 7 An Automatic Cut Off Device Should Be Attached., 8 Heather Should Be of Quartz for Immediate Output of Distilled Water. Apparatus Should Consist of High, Quality Borosilicate Boiler with Built in Water Leveller., 9 Output Water Should Be Pyrogen-free with Conductivity Less Than 1 Micro Siemen, Ph 6.9-7, Distillate, Temp 65-75 Deg C., 10 Metal Stand., 11 Automatic Cut Off Device Or Safety Control Module., 12 Power Input to Be 220-240 Vac, 50 Hz., 13 Manufacturer Should Be Iso 13485 Certified, Item No. 2, Analytical Balance, I Description of Function, 1 Electronic Balance is Required for Precision Weighing of Lab Samples, Ii Technical Specifications, 1 Weigh Accurately Up to 3rd Decimal Place, 2, Fully Automatic Time and Temperature Controlled Internal Calibration and Balance Should Be, Capable to Adjust Itself, 3 Auto Zero Setting, 4 Weighing Capacity Up to 200g, 5 Readability 0.001g, 6 Repeatability 1mg Or Less, 7 Setting Time - Less Than 2 Seconds, 8 Suitable for Internal/external Adjustment Weights, 9 Pc Connectivity, Iii Balance Should Have, 1 Liquid Crystal Display (lcd) for Display, 2 Ir Sensors for Hands Free Operation, 3 Warns If Balance is Not Correctly Levelled, 4 Automatic/manual and Detachable Draft Shield, 5 Detachable and Adjustable Terminal, 6 Facility for User Administration and Password Protection, 7 Integrated Automatic Safety Function for External Routine Operations, 8 Alphanumeric Data Entry of More Than 2 Ids, 9 Should Be Bis/ Iso Certified and Certificate to Be Provided., Iv Power Supply, 1 Power Input to Be 220-240vac, 50hz, 2 Deleted, 3, Suitable Ups with Maintenance Free Batteries for Minimum One-hour Back-up Should Be, Supplied with the System, 4 Resettable Over Current Breaker Shall Be Fitted for Protection, Item No. 3, Vertical Autoclave, 1 the Vertical Autoclave Should Have Chamber Capacity Of Effective Volume 113 Litres Or More., 2, the Chamber of Vertical Autoclave Should Be Manufactured as Per Asme Standards and, Comply with Pressure Equipment Directive, 3, the Vertical Autoclave Should Work on the Domestic Power Supply of 230 V Ac, 50 Hz, Single, Phase, 4, the Vertical Autocalve's Internal Chamber, Cover Lid and All Wetted Parts Should Be Fabricated, From Stainless Steel of 304 Grade, 5 the Vertical Autoclave Outer Body Should Be of Ss 304., 6 Temperature Range Should Be Up to 135°c and Pressure Up to 30 Psi., 7 the Vertical Autoclave?s All Joints Should Be Smooth Finished for Crevice Free Internals., 8, the Chamber Should Be Hydro Statically Tested at 1.5 Times of Its Working Pressure and, Certificate Should Be Supplied for the Same, 9, the Lid Should Be Equipped with Single Lever Lock Mechanism and Lever Handle Moulded From, Industrial Plastic, 10 the Lid Should Be Provided with Auto Purge Cum Vacuum Breaker Valve and a Manually, Operable Valve for Exhaust., 11 the Unit Should Have a Solenoid Valve for Auto Purging of Air & Normal Exhaust, 12 the Vertical Autoclave Should Have Stainless Steel Pressure Gauge with Dual Range Dial Display, in Kpa and Psi Along with a Co-related Temperature Scale for Steam in Degrees Celsius, 13 the Operations of the Unit Should Be Controlled By Touch Screen Programmable Logic, Controller with 4 Temperature Channels & 1 Pressure Channel Inbuilt., 14 the Autoclave Should Be Equipped with Touch Screen Hmi Plc., 15 Controlling of Chamber Temperature Should Be on All 4 Temperature Channels, 16, to Ensure Proper Sterilization Cycle Autoclave Should Have Facility of Connecting External, Printer Which Can Give Instant Print of All Cycle Data – Customer and Operator Name , Equipment, Number, Recipe, Hold Time, Batch Number, Date & Time, Temperature Set-point, Readings of at, Least Four Temperature Sensors, Pressure Channels F0 Summation and Cycle Status., 17 Inbuilt 6 Recipes for Different Load Should Be Available., 18 Provision of Automatic Water Filling Should Be Available., 19 the Timer Should Be Retentive & Settable Up to 95 Mins, 20, Power Fail Restoration Facility in Case of Power Failure, the Autoclave Should Give Option of, Resuming Cycle with Automatic Adjustment of Sterilization Hold Time, 21 the Unit Should Have Safety Valve to Protect the Equipment in Case of Over Pressurization, 22 the Lid Should Be Equipped with Pressure Interlock Device to Avoid Opening Under Pressure., 23 Lid Should Be Equipped with Door Switch to Avoid Cycle Start If Door is Not Locked Properly., 24 to Ensure Effective Sterilization, If Temperature Falls Below Temperature Set Point the, Sterilization Timer Should Get Automatically Adjusted., 25 the Unit Should Be Provided wit |
|
|
If you are a new user, then please
register, it's Free and then fill the form below.
If you are registered with us, just fill the form below, we will get back to you
shortly.
|
All fileds marked with '*' are compulsary.
|
|
|